Chemical Usage Guidelines
|
CHEMICAL |
CONCENTRATION |
KYNAR® HOMO-POLYMER
°C / °F
|
KYNAR® FLEX 2850
°C / °F
|
KYNAR® FLEX 2800
°C / °F
|
| Acetaldehyde |
|
NR / NR |
NR / NR |
NR / NR |
| Acetamide |
|
25 / 75 |
NR / NR |
NR / NR |
| Acetic Acid |
10% in water |
105 / 220 |
110 / 230 |
95 / 200 |
| Acetic Acid |
50% in water |
95 / 200 |
95 / 200 |
95 / 200 |
| Acetic Acid |
80% in water |
65 / 150 |
50 / 125 |
50 / 125 |
| Acetic Acid |
|
50 / 125 |
50 / 125 |
50 / 125 |
| Acetic Anhydride |
|
NR / NR |
NR / NR |
NR / NR |
| Acetone |
|
NR / NR |
NR / NR |
NR / NR |
| Acetone |
10% in water |
50 / 125 |
40 / 100 |
40 / 100 |
| Acetonitrile |
|
50 / 125 |
40 / 100 |
NR / NR |
| Acetophenone |
|
NR / NR |
NR / NR |
NR / NR |
| Acetyl Bromide |
|
50 / 125 |
50 / 125 |
50 / 125 |
| Acetyl Chloride |
|
50 / 125 |
50 / 125 |
50 / 125 |
| Acetylacetone |
|
NR / NR |
NR / NR |
NR / NR |
| Acetylene |
|
120 / 250 |
75 / 170 |
65 / 150 |
| Acrylonitrile |
|
25 / 75 |
25 / 75 |
25 / 75 |
| Adipic Acid |
|
65 / 150 |
65 / 150 |
65 / 150 |
| Air |
|
140 / 285 |
135 / 275 |
110 / 230 |
| Alcoholic Spirits |
40% Ethyl Alcohol |
95 / 200 |
95 / 200 |
95 / 200 |
| Allyl Alcohol |
|
50 / 125 |
50 / 125 |
50 / 125 |
| Allyl Chloride |
|
100 / 212 |
100 / 212 |
100 / 212 |
| Aluminum Acetate |
Aqueous solution or solid |
140 / 285 |
135 / 275 |
110 / 230 |
| Aluminum Bromide |
|
140 / 285 |
135 / 275 |
110 / 230 |
| Aluminum Chloride |
up to 40% in water |
140 / 285 |
135 / 275 |
110 / 230 |
| Aluminum Fluoride |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Aluminum Hydroxide |
|
135 / 275 |
135 / 275 |
110 / 230 |
| Aluminum Nitrate |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Aluminum Oxychloride |
|
135 / 275 |
135 / 275 |
110 / 230 |
| Aluminum Sulfate |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonia, gas |
|
NR / NR |
NR / NR |
NR / NR |
| Ammonia, Liquid |
|
NR / NR |
NR / NR |
NR / NR |
| Ammonium Acetate |
Aqueous solution or solid |
80 / 175 |
65 / 150 |
65 / 150 |
| Ammonium Alum |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonium Bifluoride |
Aqueous solution or solid |
65 / 150 |
65 / 150 |
65 / 150 |
| Ammonium Bromide |
Aqueous solution or solid |
120 / 250 |
110 / 230 |
110 / 230 |
| Ammonium Carbonate |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonium Chloride |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonium Dichromate |
Aqueous solution or solid |
120 / 250 |
135 / 275 |
110 / 230 |
| Ammonium Fluoride |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonium Hydroxide |
Up to “concentrated” |
105 / 220 |
95 / 200 |
95 / 200 |
| Ammonium Metaphosphate |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonium Nitrate |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonium Persulfate |
Aqueous solution or solid |
25 / 75 |
25 / 75 |
25 / 75 |
| Ammonium Phosphate |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonium Sulfate |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Ammonium Sulfide |
Aqueous solution or solid |
50 / 125 |
50 / 125 |
50 / 125 |
| Ammonium Thiocyanate |
Aqueous solution or solid |
135 / 275 |
135 / 275 |
110 / 230 |
| Amyl Acetate |
|
50 / 125 |
40 / 100 |
40 / 100 |
| Amyl Alcohol |
|
135 / 275 |
135 / 275 |
110 / 230 |
| Sec-Amyl Alcohol |
|
50 / 125 |
50 / 125 |
50 / 125 |
| Amyl Chloride |
|
140 / 285 |
135 / 275 |
110 / 230 |
| Aniline |
|
40 / 100 |
40 / 100 |
40 / 100 |
| Aniline Hydrochloride |
Aqueous solution or solid |
25 / 75 |
25 / 75 |
25 / 75 |
| Aqua Regia |
|
25 / 75 |
25 / 75 |
25 / 75 |
| Arsenic Acid |
Aqueous solution |
135 / 275 |
135 / 275 |
110 / 230 |
| Asphalt |
|
120 / 250 |
120 / 250 |
110 / 230 |
|
Maximum usage temperatures for KYNAR® resin with selected chemicals.
Consult your KYNAR® products representative if you have any questions or for more recent results.
- pure substance unless otherwise indicated.
- temperatures in °F have been rounded to °C in 5 degree increments
- NR indicates that KYNAR® resin is not recommended for use with the chemical at room temperature or at the temperature indicated.
- The temperatures listed are maximum values and do not take into account pressures, vacuums, mixtures, or close tolerances.
The ratings given on the previous page are a guide and do not constitute a warranty of any kind, expressed or implied, with respect to the performance of KYNAR® polyvinylidene fluroide in any specific application.
|